Microcom 400 Manual do Operador Página 48

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 100
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 47
Printer Commands Chapter 5
400 Operators Manual
40
5.3.1 SOFTWARE DIP SWITCHES AND EEPROM COMMANDS
The following commands are different from the other printer commands in that they are stored in
EEPROM, are non-volatile and configure the machine upon power-up. Once sent to the printer,
they do not need to be sent again.
The printer will only configure to the following commands after a the machine has been powered
off and then turned back on. The printer will not accept these commands until this is done.
^A ^D COMMAND
20 Change baud rate: Unless otherwise requested by the customer, the baud rate of
a 400 printer, out of the box, is 9600. (i.e. to change baud to 19200 use ^A8^D205)
0 110 Baud
1 150 Baud
2 300 Baud
3 600 Baud
4 1200 Baud
5 2400 Baud
6 4800 Baud
7 9600 Baud
8 19200 Baud