Troubleshooting Chapter 7
46 326M User’s Guide
The printer has no serial communication:
Verify that the serial cable is properly connected to the printer and an available
serial port on the host computer.
Verify that the host serial port is functioning properly.
Verify that the printer and the host serial port parameters are set exactly the
same.
Change terminal emulation parameters to 9600,n,8,1 and press two carriage
returns then use the ^E enquiry command.
Contact your Service Representative.
The label present detector is not sensing labels properly:
Is an LPD present?
Is a ^D597 dispense command being used that uses the LPD sensor?
Adjust the LPD drive using the ^D683 command to achieve proper operation.
Contact your Service Representative.